Impact Fire Protection has serviced the fire safety and prevention needs of educational facilities, hospitals, healthcare organizations, manufacturers, property managers, government institutions, restaurants and retailers in Raymond NH since 2005.
Call us now at: 800-244-7531 or check out what our clients say about our commitment to delivering innovative, safety and fire protection services and products to clients throughout Raymond NH.
Local Reviews
for Raymond, NH
Our Reviews by City
Great service
TODD - Raymond, NH
Jim was very helpful in solving our many issues.
Extinguisher Inspection
Jim - Raymond, NH
Well organized, informative, very knowledgeable
Helpful & Friendly
WENDY - Raymond, NH
Chris was very willing to answer any questions or concerns regarding our fire pump & sprinkler system. When asked about having the company perform another service for us he suggested we go to the area in question so he could get a better sense of our need. Chris is a good representation of your company
Jim C.
Jim C.
Jim C.
Derek D.
Nicholas L.
Fire Suppression Installation Installation of RG-4GM Deficiency: Improper quantity of heat detectors. One heat detector bracket is not secured to hood. Appliances are not properly protected. Control head is not properly mounted. Hydrostatic test on PCL240 overdue. System has been built using mixed generations of components (pre KK and KK1). Pull station is higher than 48" aff. Cylinder bracket for 240 is not a Pyro Chem manufactured part
Nicholas L.
4/11/18 per Troy he is awaiting some approval from their corporate office. Troy will give us a call when he receives approval from them. 5/8/18 left voicemail. Fire Suppression Inspection KITCHEN SYSTEM - QTY PYROCHEM WITH PCL-350 & PCL-240 LINKS AND NOZZLES COVERS INCLUDED Deficiency: Improper quantity of heat detectors. One heat detector bracket is not secured to hood. Appliances are not properly protected. Control head is not properly mounted. Hydrostatic test on PCL240 overdue. System has been built using mixed generations of components (pre KK and KK1). Pull station is higher than 48" aff. Cylinder bracket for 240 is not a Pyro Chem manufactured part Deficiency: All previous deficiencies still exists: Improper quantity of heat detectors. One heat detector bracket is not secured to hood. Appliances are not properly protected. Control head is not properly mounted. Hydrostatic test on PCL240 overdue. System has been built using mixed generations of components (pre KK and KK1). Pul
Jim C.
Jim C.
Nicholas L.
Portable Extinguishers and Fire Suppression Inspection FIRE EXTINGUISHERS - QTY 10 FX ALL INCLUSIVE KITCHEN SYSTEM - QTY 1 AMEREX KP-600 (TWO CYLINDERS) KS ALL INCLUSIVE Deficiency: System is non compliant due to improper coverage of the first range on main cooking line. Range is not completely under the protective hood. Needs to be moved to the right. see pictures. Also it is not protected properly. Once the range is adjusted under the hood properly we will need to adjust the nozzles accordingly. Plenum nozzles in rear hood need to be relocated to the side and not down the middle. Duct nozzle needs to be replaced in that same hood. Both ranges under that hood are improperly protected. Nozzles will need to be changed and adjusted per manufacturer specs. Customer is looking into down sizing the range that is not under the hood from a 6 burner to a 4 burner.
Jim C.
Derek D.
Berton Y.
Portable Extinguishers and Emergency / Exit Lights Inspection
Berton Y.
Portable Extinguishers Inspection
Berton Y.
Portable Extinguishers Inspection
Nicholas L.
Fire Suppression Inspection KITCHEN SYSTEM ANDUL 6.0 GALLON SSBD 2X HYDRO: (1) 2006, (1) 2013
Nicholas L.
Fire Suppression Inspection KITCHEN SYSTEM RG 6 G HYDRO: 2013 new
Chris T.
Sprinkler and Fire Pump Inspection
Clifford R.
Berton Y.
Portable Extinguishers Service Call
Berton Y.
Deliver New 15LB CO2 and 10ABC fire extinguishers
Berton Y.
Deliver New 15LB CO2 Fire Extinguisher
Berton Y.
Replace Emergency Light
Berton Y.
Replace Emergency Light
Berton Y.
Replace Emergency Light
Berton Y.
Replace Emergency Light