Tri State Fire Protection has serviced the fire safety and prevention needs of educational facilities, hospitals, healthcare organizations, manufacturers, property managers, government institutions, restaurants and retailers in Plaistow NH since 2005.

Call us now at: 800-244-7531 or check out what our clients say about our commitment to delivering innovative, safety and fire protection services and products to clients throughout Plaistow NH.

Local Reviews
for Plaistow, NH

Rated 5.0 out of 5 stars based on 1 customer reviews

Our Reviews by City

Bow, NH (2)
Derry, NH (10)
Keene, NH (24)
Lee, NH (3)
Nashua, NH (120)
Rye, NH (5)


Great Service!





Nicholas L.

Nicholas L.

Recently one of our licensed technicians was at your location to perform the service on your fire suppression system. During that inspection the following deficiency was found on order 15042253. Gas Station Canopy Suppression SystemAll Kidde IND50 cylinders (4) are past due for the 12 year hydrotest services. This includes service swap cylinders, paint/prime service, new NFPA collars, new safety plugs and valve rebuild kits No k-class fire extinguisher in kitchen where fryer is located CLIENT RESPONSIBILITY: Contact fire alarm company and electrician to properly tie-in gas station XV control head. Currently there is no alarm or electrical shut downRepair of these deficiencies is essential to overall life safety. Please see the attached compliance quote. If you have any questions, feel free to call me. Thank you Mike McDonald 603-988-5512Gas Station Suppression Repair Gas station is non compliant due to system cylinders need hydro testing. This test must be performed every 12 year

Near Newton Rd, Plaistow, NH 03865
Nicholas L.

Nicholas L.

FIRE EXTINGUISHERS - QTY 3 GAS STATION - QTY 1Portable Extinguishers and Gas Station Suppression Inspection Deficiency: Gas station is non compliant due to system cylinders need hydro testing. This test must be performed every 12 years per NFPA. There is no fire alarm tied into the system. Pumps do not shut down apon system activation. Will need to add class k fx in kitchen due to auto fry system

Near Newton Rd, Plaistow, NH 03865
Nicholas L.

Nicholas L.

Gas Station Suppression, Emergency / Exit Lights, and Portable Extinguishers Inspection GAS STATION - QTY UNKNOWNGS DO FX AT SAME TIME EMERGENCY LIGHT SPOT CHECK - REPAIR AS NEEDEDEL TO BE DONE WITH GS FIRE EXTINGUISHERS - QTY UNKNOWNFX TO BE DONE WITH KS Deficiency for Pyro Chem ECH3 ATD80SBC: Gas station: System deficiency still exist. see previous paperwork.see pictures Also found One cylinder above pumps 5/6 has a leak and needs to be swapped. second cylinder in from store side of canopy

Near Danville Rd, Plaistow, NH 03865
Nicholas L.

Nicholas L.

Portable Extinguishers Inspection FIRE EXTINGUISHERS - QTY 1

Near Plaistow Rd, Plaistow, NH 03865
Michael S.

Michael S.

Near Plaistow Rd, Plaistow, NH 03865
Derek D.

Derek D.

Near Plaistow Rd, Plaistow, NH 03865
Berton Y.

Berton Y.

Portable Extinguishers Inspection

Near Mayray Ave, Plaistow, NH 03865
Berton Y.

Berton Y.

Portable Extinguishers and Emergency / Exit Lights Inspection

Near Plaistow Rd, Plaistow, NH 03865
Berton Y.

Berton Y.

Portable Extinguishers Inspection

Near Plaistow Rd, Plaistow, NH 03865
Brenda K.

Brenda K.

Annual fire extinguisher inspection at a fish and game club

Near Mayray Ave, Plaistow, NH 03865