Fire Safety Systems | Northborough MA

Fire Safety Systems | Northborough MA 2018-12-06T16:02:32+00:00

Call us now at: 800-244-7531 or check out what our clients say about our commitment to delivering innovative, safety and fire protection services and products to clients throughout Northborough MA.

Local Reviews
for Northborough, MA

Rated 5.0 out of 5 stars based on 3 customer reviews

Our Reviews by City

Bow, NH (2)
Derry, NH (10)
Keene, NH (24)
Lee, NH (3)
Nashua, NH (119)
Rye, NH (5)


Great Service




Tri State services 87 of our locations and does a great job. Their customer service is excellent and their pricing is reasonable.


Nick was fantastic




Nick provided the service for our retrofit/repair/code work whatever this job is titled. He was nothing but professional and courteous. I would recommend him to anyone for their work with Tri-State. I we are able to request technicians for future jobs, he would be my go to guy. Thanks for the great job.


Professional and on time




everyone was very professional and on time made sure that everybody was on the same page before the work started, testing was completed and successful as always on top of the inspection.


mark g.

mark g.

Near Shops Way, Northborough, MA 01532
Derek D.

Derek D.

Near Shops Way, Northborough, MA 01532
Nicholas L.

Nicholas L.

Kitchen Hood Suppression System - NON COMPLIANT Recently one of our licensed technicians was at your location to perform the service on your fire suppression system. During that inspection the following deficiencies were found on order 14236181Nozzle for first fryer is installed too low per Amerex requirements. Nozzle must sit between 40"-50" inches. Currently at 30" The 10 burner range has a back shelf. The nozzles installed would protect this unit if the back shelf was not in place. If the back shelf remains the line would need to be repiped under the shelf with nozzle type 11982 protection (5 nozzles total) Pipe one additional appliance to the smaller cylinder to allow proper flow capacity on the larger cylinder. (only supports 11 flows and has 11.5 piped into it). The smaller cylinder can spare 2 flows if back shelf is removed or 3 if the shelf remains and new coverage added. Replace and update the 3 male threaded nozzles over the griddle and fryers that are no longer supported b

Near Main St, Northborough, MA 01532
Nicholas L.

Nicholas L.

Fire Suppression Inspection Kitchen System -R 102 7.5 G Hydro: 2012 newKS TO BE DONE WITH FX & EL

Near Shops Way, Northborough, MA 01532
Derek D.

Derek D.

Near Hudson St, Northborough, MA 01532
Derek D.

Derek D.

Near E Main St, Northborough, MA 01532
Derek D.

Derek D.

Near E Main St, Northborough, MA 01532
Robert O.

Robert O.

Near Bearfoot Rd, Northborough, MA 01532
Nicholas L.

Nicholas L.

The appliance line has recently been modified. The fire suppression system will need to be re-piped to accommodate these changes. Tri State proposes to re-pipe the appliance line.Fire Suppression Repair Kitchen System -R 102 7.5 G Hydro: 2012 newKS TO BE DONE WITH FX & EL system is non compliant due to improper coverage of the appliances. customer rearranged the line by switching the fryers and one of the griddle. see pictures. These appliances need to be moved back where they were or the appliance line will need to be repiped. - repair

Near Shops Way, Northborough, MA 01532
Nicholas L.

Nicholas L.

Kitchen System -R 102 7.5 G Hydro: 2012 newKS TO BE DONE WITH FX & EL Deficiency: system is non compliant due to improper coverage of the appliances. customer rearranged the line by switching the fryers and one of the griddle. see pictures. These appliances need to be moved back where they were or the appliance line will need to be repiped. Fire Suppression Inspection

Near Shops Way, Northborough, MA 01532
Nicholas L.

Nicholas L.

Emergency / Exit Lights, Portable Extinguishers, and Fire Suppression Inspection EMERGENCY LIGHTSALL INCLUSIVEEL TO BE DONE WITH KS EXTINGUISHERS - QTYALL INCLUSIVEFX TO BE DONE WITH KS Kitchen System -R 102 7.5 G Hydro: 2012 newKS TO BE DONE WITH FX & EL

Near Shops Way, Northborough, MA 01532
Douglas T.

Douglas T.

Amerex suppression system inspected and certified