Impact Fire Protection has serviced the fire safety systems and prevention needs of educational facilities, hospitals, healthcare organizations, manufacturers, property managers, government institutions, restaurants and retailers in Natick MA since 2005.
Call us now at: 800-244-7531 or check out what our clients say about our commitment to delivering innovative, safety and fire protection services and products to clients throughout Natick MA.
Local Reviews
for Natick, MA
Our Reviews by City
Owner
ALEX - Natick, MA
great service
ALEX - Natick, MA
Nicholas Lopez is a very knowledgeable person.
director of maintenance
ELIAS - Natick, MA
great communication good techician
maintenance director
ELIAS - Natick, MA
great tenichian performed a great job
Jim C.
Jim C.
mark g.
mark g.
mark g.
mark g.
mark g.
Shem H.
Nicholas L.
Fire Suppression and Portable Extinguishers Inspection KITCHEN SYSTEM -(1) 3-gallon Pyro-Chem Kitchen Knight II system ALL INCLUSIVE Commission 3-gallon pyro-chem system. customer has all parts. system just needs to be assembled & inspected Inspect 2 FX
mark g.
Ben G.
Derek D.
mark g.
Nicholas L.
Portable Extinguishers and Fire Suppression Inspection FIRE EXTINGUISHERS - QTY UNKNOWN FX TO DO KS AT SAME TIME KITCHEN SYSTEM - QTY 1 KS TO DO FX AT SAME TIME
mark g.
Nicholas L.
Fire Suppression Inspection KITCHEN SYSTEM - ZONE 2 PCL 300 HYDRO: 2003 KS TO BE DONE WITH FX
Nicholas L.
Kitchen Hood Suppression - Ansul Red Steel Cylinder The kitchen hood fire suppression system protecting the cook line has recently undergone a semi-annual certification at the above facility. During this inspection, it was noted that the Ansul brand red painted steel tanks are present on the system. This manufacturer has since stopped producing these tanks due to an increased chance of corrosion that can lead to system failure if needed to react to a fire hazard. Due to this integrity issue, Ansul now manufacturers stainless steel agent cylinders to prevent any chance of corrosion/system failure. Please review the below proposal to replace the red painted mild steel tanks that are currently installed. Please feel free to contact me with any questions. Mike McDonald 603-988-5512 Fire Suppression Repair Red mild steel cylinder should be replaced with stainless steel cylinder. - repair
Nicholas L.
Fire Suppression Inspection KITCHEN SYSTEM - ZONE 2 PCL 300 HYDRO: 2003 KS TO BE DONE WITH FX
mark g.
Nicholas L.
Fire Suppression Inspection KITCHEN SYSTEM - QTY 1 KP375- 2009 KS TO DO FX AT SAME TIME ST PART# 7001
Shem H.
Nicholas L.
Fire Suppression Inspection Kitchen System - Zone 2 R 102 9.0 G SSBD - main line Hydro: (3) 2015 new R 102 3.0 G - secondary line Hydro: 2015 new
Nicholas L.
Fire Suppression Repair Kitchen Suppression Parts
Nicholas L.
Fire Suppression Inspection KITCHEN SYSTEM - ZONE 2 Ansul 4.5 G SSBD - HYDRO: 2010 Deficiency: Deli suppression: Expellant gas cartridge is incorrect, and was also improperly hydrostatically tested (no Ansul markings on burst disk). There are 2 duct nozzles on 1.5gal cylinder which is not allowed by the manufacturer. Single tank enclosure is missing its cover.