Fire Safety Systems | Fitchburg MA

Fire Safety Systems | Fitchburg MA 2018-11-30T15:53:06+00:00

Tri State Fire Protection has serviced the fire safety and prevention needs of educational facilities, hospitals, healthcare organizations, manufacturers, property managers, government institutions, restaurants and retailers in Fitchburg, MA since 2005.

Call us now at: 800-244-7531 or check out what our clients say about our commitment to delivering innovative, safety and fire protection services and products to clients throughout Fitchburg, MA.

Local Reviews
for Fitchburg, MA

Rated 5.0 out of 5 stars based on 2 customer reviews

Our Reviews by City

Bow, NH (2)
Derry, NH (10)
Keene, NH (24)
Lee, NH (3)
Nashua, NH (119)
Rye, NH (5)


Great Service




Pleasant and informative


Great service, knowledgeable, polite





mark g.

mark g.

Near Boutelle St, Fitchburg, MA 01420
Nicholas L.

Nicholas L.

Fire Suppression Inspection KITCHEN SYSTEM - QTY 1 PCL-460 - HYDRO 2017KS ALL INCLUSIVE KS TO DO FX @ SAME TIME

Near Lunenburg St, Fitchburg, MA 01420
Nicholas L.

Nicholas L.

Fire Suppression Inspection Semiannual Kitchen Fire Suppression System Inspection - QTY 2Main Hood - PCL-460 - HYDRO 2011 Small Hood - KP-275 - HYDRO 2007 Deficiency: Main kitchen system: System is non compliant due to improper coverage of the lava chargrill and range with back shelf. Chargrill currently has 2x 1H nozzles, these need to be changed to 3x 1L nozzles and piped under the shelf for proper protection. Range currently has a 1H and a 2H, these need to be changed to 2x 2L due to back shelf.Lava Rock Char-Broiler (624 in. 2 (40257 mm 2) x 26 in. (660 mm) longest side maximum) Note: Synthetic rock charbroilers are distinguished by the use of lava, pumice, or synthetic rocks that are used for cooking. One nozzle is available for lava rock char-broiler protection: High proximity and low proximity. The 2L Nozzle (Part No. 551027) is used for high proximity lava rock char-broiler protection. This nozzle is a two flow nozzle. The nozzle must be located anywhere within the perimete

Near Duck Mill Rd, Fitchburg, MA 01420
Nicholas L.

Nicholas L.

Kitchen Hood Suppression System - NON COMPLIANT Recently one of our licensed technicians was at your location to perform the service on your fire suppression system. During that inspection the following deficiencies were found on order 14196023Correct system deficienciesRepair of these deficiencies is essential to overall life safety. Please see attached compliance quote. If you have any questions, feel free to call me. Thank you Mike McDonald 603-988-5512Fire Suppression Repair The nozzles for the appliance protection are all outside the perimeter of the appliances. The fryer nozzles are not in the proper position. The griddle requires a second 11982 nozzle for its protection.the nozzles for the 6 burner (with back shelf)protection are not the proper ones. The nozzle for the griddle protection is not the proper one ( there is an upright broiler on top of the griddle). The nozzle for the upright broiler is not the proper one. All the pipe and conduit outside the hood is painted

Near Lunenburg St, Fitchburg, MA 01420
Nicholas L.

Nicholas L.

Kitchen Hood Suppression System - NON COMPLIANT Recently one of our licensed technicians was at your location to perform the service on your fire suppression system. During that inspection the following deficiencies were found on order 14196023Correct system deficienciesRepair of these deficiencies is essential to overall life safety. Please see attached compliance quote. If you have any questions, feel free to call me. Thank you Mike McDonald 603-988-5512Fire Suppression Repair The nozzles for the appliance protection are all outside the perimeter of the appliances. The fryer nozzles are not in the proper position. The griddle requires a second 11982 nozzle for its protection.the nozzles for the 6 burner (with back shelf)protection are not the proper ones. The nozzle for the griddle protection is not the proper one ( there is an upright broiler on top of the griddle). The nozzle for the upright broiler is not the proper one. All the pipe and conduit outside the hood is painted

Near Lunenburg St, Fitchburg, MA 01420
Michael S.

Michael S.

Near Clarendon St, Fitchburg, MA 01420
Michael S.

Michael S.

Near Fairmount St, Fitchburg, MA 01420
Michael S.

Michael S.

Near Fairmount St, Fitchburg, MA 01420
Michael S.

Michael S.

Near Prichard St, Fitchburg, MA 01420
mark g.

mark g.

Near Fairmount St, Fitchburg, MA 01420
mark g.

mark g.

Near Plymouth St, Fitchburg, MA 01420
mark g.

mark g.

Near Clarendon St, Fitchburg, MA 01420
mark g.

mark g.

Near Prichard St, Fitchburg, MA 01420
mark g.

mark g.

Near Academy St, Fitchburg, MA 01420
Michael S.

Michael S.

Near John Fitch Hwy, Fitchburg, MA 01420
mark g.

mark g.

Near Townsend St, Fitchburg, MA 01420
Nicholas L.

Nicholas L.

Customer is COD. see comment below for pricingFire Suppression Inspection KITCHEN SYSTEM - QTY 1 PCL-460KS ALL INCLUSIVE Deficiency: System is non compliant due to system cylinder needing hydro testing. Cylinder (PCL460) is dated for 2005 and is due for hydro every 12 years per nfpa.

Near Lunenburg St, Fitchburg, MA 01420
Robert O.

Robert O.

Near Oak Hill Rd, Fitchburg, MA 01420
Brenda K.

Brenda K.

Annual inspection and service of Fire Extinguishers.

Near Boutelle St, Fitchburg, MA 01420
Douglas T.

Douglas T.

Suppression system inspection complete

Near John Fitch Hwy, Fitchburg, MA 01420